Specifications Membrane: HPLC certified PTFE, w/polypropylene support Maximum operating temperature: 110 °C Housing: Medical grade, virgin polypropylene Autoclave: Sterilize by dry heat at 121 °C for 15 minutes Applications HPLC and organic-solvent sample preparation and clean-up Dissolution sample analysis General sample preparation Elevated temperature samples, caustic or acidic solutions Chemical Incompatibilities Perchloric acid Methylene chloride (limited exposure) Dioxane, DMF, formic acid >50%
Choice™ PTFE (Hydrophilic) Syringe Filters
Use Thermo Scientific™ Choice™ PTFE Hydrophilic Syringe Filters for filtration of aggressive organic, highly basic or hot solutions, and as transducer protectors. These Choice Syringe Filters can filter aqueous solutions without the need for pre-wetting with an alcohol. They provide cleaner sample extracts by removing interfering materials and fine particles down to the rated pore size.
Сatalog number:
CH4525-NPL
Category: Syringeless and Syringe Filters
Description
Additional information
Disposable |
Yes |
---|---|
Material |
PTFE (Hydrophilic) |
Material (Membrane) |
PTFE (Hydrophilic) |
Pore Size |
0.45 μm, 0.2 μm |
Sterility |
Non-sterile |
For Use With (Application) |
HPLC, SPE |
Housing Material |
Solvent Resistent, Low-Extractable Polypropylene |
No. per Pack |
100 |
Prefilter |
No |
Pressure Rating |
90 psi |
Product Line |
Choice |
Type |
Syringe Filter |
Diameter (Metric) |
25 mm, 13 mm |
Unit Size |
Pack of 100 |
Reviews (0)
Be the first to review “Choice™ PTFE (Hydrophilic) Syringe Filters” Cancel reply
Shipping & Delivery
Related products
Сatalog number:
728-2045PK
Nalgene™ Syringe Filters, Non-sterile
Thermo Scientific™ Nalgene™ syringe filters are built to meet your lab’s clarification and sterilization needs. Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications. Whether your research necessitates prefiltration, sample preparation, sterile filtration, laboratory filtration, or gas venting, Nalgene syringe filters are lab essentials.
Сatalog number:
CH4525-RC
Choice™ Regenerated Cellulose Syringe Filters
Use Thermo Scientific™ Choice™ Regenerated Cellulose (RC) Syringe Filters for low nonspecific binding applications as well as for tissue culture media filtration and general biological sample filtration. These syringe filters provide cleaner sample extracts by removing interfering materials and fine particles down to the rated pore size.
Сatalog number:
F2513-17
Target2™ PES (Polyethersulfone) Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Target2™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Target2 PES (Polyethersulfone) Syringe Filters are used for ion chromatography, tissue culture filtration and filtration of proteins and nucleic acids, as well as for filtration of high-temperature liquids.
Сatalog number:
F2502-3
Target2™ PTFE Syringe Filters, 0.45μm, 30mm, with Pre-Filter
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Target2™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Target2 PTFE Syringe Filters are used for general biological filtration. They are especially well-suited for applications where high protein recovery is desired.
Сatalog number:
CH4525-PVH
Choice™ PVDF (Hydrophobic) Syringe Filters
Thermo Scientific™ Choice™ PVDF (hydrophobic) Syringe Filters are a good option for general biological filtration. They are especially well-suited for applications where high protein recovery is desired. Choice PVDF (hydrophobic) Syringe Filters require pre-wetting with an alcohol for aqueous samples. They provide cleaner sample extracts by removing interfering materials and fine particles down to the rated pore size.
Сatalog number:
44525-NPL
Titan3™ PTFE (Hydrophilic) Syringe Filters
Сatalog number:
F2500-20
Target2™ GMF (Glass MicroFiber) Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Target2™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Target2 GMF (Glass MicroFiber) Syringe Filters are often used for dissolution testing. They are also well-suited for general filtration applications.
Сatalog number:
45025-NN
Titan3™ Nylon Syringe Filters
Offering low extractable membranes and housing, Thermo Scientific™ Titan3™ Nylon Syringe Filters are HPLC performance tested, and color-coded to easily select the correct membrane and pore size. An enhanced Luer Lock inlet prevents leakage. A 1mm boro-silicate glass pre-filter is provided with most 30mm devices, pressure rated to 120psi. This is particularly beneficial with high solids samples that have larger-size particulates. An internal ring provides more strength to the housing which prevents leakage and bursting. Titan3 Syringe Filters are packed in re-usable rigid transparent and color-coded containers.
Reviews
There are no reviews yet.