Specifications Membrane: HPLC certified PVDF Maximum operating temperature: 100 °C Housing: Medical grade, virgin polypropylene Autoclave: Sterilize by dry heat at 121 °C for 15 minutes Applications HPLC and organic-solvent sample preparation and clean-up Protein-based samples with high non-specific binding Environmental water samples Chemical Incompatibilities DMF, DMSO, MEK, acetone and most caustic solutions >6N
Choice™ PVDF (Hydrophobic) Syringe Filters
Thermo Scientific™ Choice™ PVDF (hydrophobic) Syringe Filters are a good option for general biological filtration. They are especially well-suited for applications where high protein recovery is desired. Choice PVDF (hydrophobic) Syringe Filters require pre-wetting with an alcohol for aqueous samples. They provide cleaner sample extracts by removing interfering materials and fine particles down to the rated pore size.
Сatalog number:
CH4525-PVH
Category: Syringeless and Syringe Filters
Description
Additional information
Disposable |
Yes |
---|---|
Material |
PVDF (Hydrophobic) |
Material (Membrane) |
PVDF (Hydrophobic) |
Pore Size |
0.45 μm, 0.2 μm |
Sterility |
Non-sterile |
For Use With (Application) |
HPLC, SPE |
Housing Material |
Solvent Resistent, Low-Extractable Polypropylene |
No. per Pack |
100 |
Prefilter |
No |
Pressure Rating |
90 psi |
Product Line |
Choice |
Type |
Syringe Filter |
Diameter (Metric) |
25 mm, 13 mm |
Unit Size |
Pack of,100, Pack of 100 |
Reviews (0)
Be the first to review “Choice™ PVDF (Hydrophobic) Syringe Filters” Cancel reply
Shipping & Delivery
Related products
Сatalog number:
45025-NN
Titan3™ Nylon Syringe Filters
Offering low extractable membranes and housing, Thermo Scientific™ Titan3™ Nylon Syringe Filters are HPLC performance tested, and color-coded to easily select the correct membrane and pore size. An enhanced Luer Lock inlet prevents leakage. A 1mm boro-silicate glass pre-filter is provided with most 30mm devices, pressure rated to 120psi. This is particularly beneficial with high solids samples that have larger-size particulates. An internal ring provides more strength to the housing which prevents leakage and bursting. Titan3 Syringe Filters are packed in re-usable rigid transparent and color-coded containers.
Сatalog number:
54525-RC
Titan3™ Regenerated Cellulose Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Titan3™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Titan3 Regenerated Cellulose Syringe Filters are used for low nonspecific binding applications as well as tissue culture media filtration and general biological sample filtration.
Сatalog number:
F2513-16
Target2™ Cellulose Acetate Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Target2™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Target2 Cellulose Acetate Syringe Filters are a good choice for filtration of tissue culture media, or for filtration of sensitive biological samples.
Сatalog number:
726-2545
Nalgene™ Sterile Syringe Filters
Thermo Scientific™ Nalgene™ syringe filters are built to meet your lab’s clarification and sterilization needs. Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications. Whether your research necessitates prefiltration, sample preparation, sterile filtration, laboratory filtration, or gas venting, Nalgene syringe filters are lab essentials.
Сatalog number:
44525-PV
Titan3™ PVDF Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Titan3™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Titan3 PVDF Syringe Filters are used for general biological filtration. They are especially well-suited for applications where high protein recovery is desired.
Сatalog number:
44525-CA
Titan3™ Cellulose Acetate Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Titan3™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Titan3 Cellulose Acetate Syringe Filters are a good choice for filtration of tissue culture media, and for filtration of sensitive biological samples.
Сatalog number:
CH4525-RC
Choice™ Regenerated Cellulose Syringe Filters
Use Thermo Scientific™ Choice™ Regenerated Cellulose (RC) Syringe Filters for low nonspecific binding applications as well as for tissue culture media filtration and general biological sample filtration. These syringe filters provide cleaner sample extracts by removing interfering materials and fine particles down to the rated pore size.
Сatalog number:
728-2045PK
Nalgene™ Syringe Filters, Non-sterile
Thermo Scientific™ Nalgene™ syringe filters are built to meet your lab’s clarification and sterilization needs. Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications. Whether your research necessitates prefiltration, sample preparation, sterile filtration, laboratory filtration, or gas venting, Nalgene syringe filters are lab essentials.
Reviews
There are no reviews yet.