• Quote Request
  • Certificates
Golden Bio Technologies Golden Bio Technologies
  • Home
  • Shop
  • About us
  • Contact us
Login / Register
Sign inCreate an Account

Lost your password?
10 items 10 items /
Menu
Golden Bio Technologies Golden Bio Technologies
Click to enlarge
Home Shop REAGENTS/ASSAYS Rapid Tests (AMP) Amphetamine Test (Cassette) GBR-3408
Ion Torrent S5TM Sequencer
Back to products
CK-MB Whole Blood/Serum/Plasma Test (Cassette) GBR-3314

(AMP) Amphetamine Test (Cassette) GBR-3408

Directions for use:

      1. Remove the test device from its foil wrapper by tearing along the slice.
      2. Using the specimen dropper, withdraw urine sample from the specimen cup and slowly dispense three drops (approx 120 UI) into the circular sample well.
      3. Be careful not to overfill the absorbent pad.
      4. Read results after 5 minutes.

DO NOT INTERPRET RESULTS AFTER 10 MINUTES

 

Precautions:

      • For medical and other professional in vitro diagnostic use only.
      • Do not use after expiration date.
      • The test device should remain in the sealed pouch until use.
      • The test is for single use only. Do not reuse.
      • Wearing gloves is recommended.

 

Storage and Stability:

      • Store as packaged in the sealed pouch at anywhere between 2-30° (36-46°F).
      • The test is stable through to the expiration date printed on the sealed pouch.
      • The test must remain in the pouch until use.
      • Do not freeze.
      • Do not use beyond the expiration date.

 

Results:

    • Positive: One colour line appears in the control region. No line appears in the test region.
    • Negative: Two lines appear; one colour line in the control region, and another apparent colour line in the test region.
    • Invalid: Control line fails to appear.
Compare
Add to wishlist
Categories: Drug of Abuse Tests, Rapid Tests Tag: (AMP) Amphetamine Test (Cassette) GBR-3408
Share:
  • Additional information
  • Reviews (0)
  • Shipping & Delivery
Additional information
CAT NO.

GBR-3408

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “(AMP) Amphetamine Test (Cassette) GBR-3408” Cancel reply

Your email address will not be published. Required fields are marked *

Shipping & Delivery

Related products

Compare

(BUP) Buprenorphine Test (Strip) GBR-3415

Rapid Tests, Drug of Abuse Tests

ALLTEST Buprenorphine BUP urine drug testing strips

Key points about Buprenorphine BUP drug test strips:
  • 10ng sensitivity.
  • Detects Buprenorphine (also known as Subutex) for up to 5 days after last use
  • 99.8% accuracy
  • Quick and easy to use urine drug test strip
  • Read result in 3-5 minutes
  • Manufactured by ALLTEST
  • Full CE & international quality certified test.
  • Each drug test kit is an individually foil wrapped urine drug test strip.
Add to wishlist
Add To Quote
Quick view
Compare

Peanut Test (Cassette) GBR-3113

Rapid Tests, ALLERGY TESTS
Peanut ELISA Test kit Peanut ELISA Test kit Intended Use Peanut ELISA Kit that is an Enzyme Immunosorbent Assay for the qualitative determination of Peanut in food. The Peanut ELISA Kit is a rapid and sensitive Food Allergen ELISA Kit which is designed to provide a sensitive and convenient method for screening food samples for peanut residues. This Peanut ELISA Kit represents a highly sensitive detection system which is particularly capable of the quantification of peanut residues in cookies, cereals, ice cream, and chocolate. Peanut ELISA Kit Components: • Microplate: 96 wells coated with anti-peanut antibodies • Extraction and sample dilution buffer • Peanut Standards • Conjugate anti- Peanut -peroxidase • Substrate Solution • Stop Solution • Washing Solution Method Principle This Diagnostic Automation/ Cortez Diagnostics Inc. Peanut ELISA Kit is a quantitative test is based on the principle of the enzyme linked immunosorbent assay. An antibody directed against peanut proteins is bound on the surface of a microplate wells. Peanut containing samples or standards are given into the wells of the microtiter plate on the Peanut ELISA Kit. For further details please refer to complete instructions manual supplied with the product. Background Information Peanut belongs to the legumes, with a very high content of protein constituting about 25% of it. Many of these allergenic protein are present in relative high amounts. For this reason peanut represents one of the most important food allergens. For peanut allergic persons, hidden peanut allergens in food are a critical problem. Already very low amounts of peanuts can cause allergic reactions, which may lead to anaphylactic shock in severe cases. Because of this, peanut allergic persons must strictly avoid the consumption of peanuts or peanut containing food. Cross-contamination, mostly in consequence of the production process is often noticed. The chocolate production process is a representative example. This explains why in many cases the existence of peanut residues in foods cannot be excluded. Thus, sensitive detection systems, like this Peanut ELISA Kit, for peanut residues in foodstuffs are required.
Add to wishlist
Add To Quote
Quick view
Compare

CEA Serum Test (Strip 5mm) GBR-3213

Rapid Tests, Cancer Tests
Add to wishlist
Add To Quote
Quick view
Compare

(BAR) Barbiturates Test (Strip) GBR-3411

Rapid Tests, Drug of Abuse Tests
Barbiturates Urine Drug Test Strip is a rapid, visual, sensitive immunoassay test. The test is based on the principle of the high affinity and specific antibody and antigen reaction. It can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Barbiturates in urine at a cut-off level of 300ng/ml. Specifications • High sensitivity, simple, easy. • Accuracy:>99%. • CE & ISO approved. • Specimen:Urine. • Model No:BAR-U01D.
Add to wishlist
Add To Quote
Quick view
Compare

AFP Serum Test (Strip 5mm) GBR-3211

Rapid Tests, Cancer Tests
Add to wishlist
Add To Quote
Quick view
Compare

(BZO) Benzodiazepine Test (Cassette) GBR-3412

Rapid Tests, Drug of Abuse Tests
Note:Could be customized under your request Specifications 1. High sensitivity, simple, easy. 2. Accuracy: >99%. 3. CE & ISO approved. 4. Specimen: Urine. 5. Model No:BZO-U02D 1.Application The BZO Rapid Test Device (Urine) detects Benzodiazepines through visual interpretation of color development on the Device. Drug conjugates are immobilized on the test region of the membrane. During testing, the specimen reacts with antibodies conjugated to colored particles and precoated on the sample pad. The mixture then migratesthrough the membrane by capillary action, and interacts with reagents on the membrane. If there are insufficient drug molecules in the specimen, the antibody-colored particle conjugate will bind to the drug conjugates, forming a colored band at the test region of the membrane. Therefore, a colored band appears in the test region when the urine is negative for the drug. If drug molecules are present in the urine above the cut-off concentration of the test, they compete with the immobilized drug conjugate on the test region for limited antibody binding sites. This will prevent attachment of the antibody-colored particle conjugate to the test region. Therefore, the absence of a colored band at the test region indicates a positive result. The appearance of a colored band at the control region serves as a procedural control, indicating that the proper volume of specimen has been added and membrane wicking has occurred. 2. Usage: Allow test device,urine specimen,and/or controls to equilibrate to room temperature (15-30°C) prior to testing.  
Add to wishlist
Add To Quote
Quick view
Placeholder
Compare

Histamine GBR-3114

Rapid Tests, *NEW* ALLERGY TESTS
Add to wishlist
Add To Quote
Quick view
Compare
Сatalog number: GBR-3315

Myoglobin Whole Blood/Serum/Plasma Test (Cassette) GBR-3315

Rapid Tests


Add to wishlist
Add To Quote
Quick view
Goldenbiotechnologies-EMEADIS-TICARET-LIMITED-SIRKETI

Golden Bio Technologies Corporation is a leading manufacturer and supplier of research and clinical laboratory equipment and reagents for worldwide diagnostics and research markets. It has been dedicated to helping develop an excellent diagnostics healthcare system nationwide by looking for affordable and most recent innovations in in-vitro diagnostics.

Contact

  • 8920 Vernon Ave., Suite 130, Montclair, CA 91763, USA
  • Phone: +1-909-931-1300
  • Fax: +1-909-360-4140
  • Email: info@goldenbiotechnologies.com

Quick Links

    • Home
    • Shop
    • About Us
    • Assay Development
    • R&D Services
    • Contact Us

Categories

    • Consumables
    • Equipments
    • Reagents/Assays
    • PCR
    • FERTILITY-Hormone
    • Ovulation Tests
Goldenbiotechnologies 2022
payments
  • Home
  • Shop
  • About us
  • Contact us
  • Wishlist
  • Compare
  • Login / Register
Shopping cart
close
Start typing to see products you are looking for.