• Quote Request
  • Certificates
Golden Bio Technologies Golden Bio Technologies
  • Home
  • Shop
  • About us
  • Contact us
Login / Register
Sign inCreate an Account

Lost your password?
4 items 4 items /
Menu
Golden Bio Technologies Golden Bio Technologies
Sold out
Awaiting product image
Click to enlarge
Home Shop Thermofisher scientific products Filters and Filtration Ultrafiltration Filters and Devices Pierce™ Protein Concentrators PES, 50K MWCO, 0.5–100 mL
Placeholder
Nalgene™ Rectangular Amber HDPE Bottles
Back to products
Placeholder
Nalgene™ Narrow-Mouth Amber HDPE Economy Bottles

Pierce™ Protein Concentrators PES, 50K MWCO, 0.5–100 mL

Easily and quickly concentrate 50K molecular weight cutoff (MWCO) protein and biological samples with Thermo Scientific Pierce Protein Concentrators PES (polyethersulfone), which are disposable centrifugation devices that enable fast sample recovery and a short processing time. These concentrator columns can be used with standard microcentrifuge equipment, and samples can be collected without the need for invert spinning. Samples can be concentrated with or without desalting.

Clear
Compare
Add to wishlist
Сatalog number: 88542 Category: Ultrafiltration Filters and Devices
Share:
  • Description
  • Additional information
  • Reviews (0)
  • Shipping & Delivery
Description

For protein and other biological samples, such as nucleic acids with a 50K MWCO, Thermo Scientific Pierce Protein Concentrators PES offer rapid protein concentration, excellent sample recovery, and instrument compatibility. These centrifugal devices feature a high-flux polyethersulfone (PES) membrane for concentration, desalting, and buffer exchange of biological samples. This product has a molecular-weight cutoff of 50K and can be used for processing sample volumes of 0.5–100 mL. Features of 50K MWCO Protein Concentrators PES include: • Rapid protein concentration —sample concentration of 10- to 30-fold can be achieved in 15 or fewer minutes • Excellent protein recovery —typical protein recovery is >90% (when the sample mass is at least two-fold greater than the posted MWCO) • Instrument-compatibility —a standard microcentrifuge with swinging (except 88504) or fixed-angle rotors can be used; sample can be collected and recovered without invert spinning • Versatile —easily perform sample concentration, diafiltration, or buffer-exchange of biological samples For easy identification, the MWCO value is etched on the side of each device. To assist with sample addition and recovery, a clear window with graduations is located on the side of each device enabling visual determination of the retentate volume. The vertical design of the membrane allows high-flux rates, low non-specific binding, and negligible protein aggregation on the membrane and provides reliable and consistent results for processing sample volumes between 0.5 and 100 mL. Typical protein recovery is 90% when the mass of the proteins in the sample is at least two-fold greater than the MWCO of the device used. For example, when using IgG (MW ~150K) samples, use the 5K, 10K, 30K, or 50K MWCO Concentrators. Sample concentration of 10- to 30-fold can be achieved within 15 minutes. Protein Concentrators PES applications • Protein concentration of tissue culture media, antiserum, or monoclonal antibody preparations • Concentration of protein peaks following gel-permeation chromatography • Removal of unincorporated label following protein modification reactions • Concentration and desalt/buffer-exchange after elution of protein from ion-exchange, hydrophobic interaction (HIC), metal chelate, or affinity chromatography columns • Separation of different sized molecules Pierce Protein Concentrators PES contain a membrane rated for retaining molecules with a molecular weight at least two-fold greater than the MWCO rating of the PES membrane within the device. Reduced recovery may occur when using a concentrator with molecules smaller than the recommended mass. Protein recovery will vary depending on the specific protein in the sample and its starting concentration. The dead-stop volume for the 0.5 mL, 2–6 mL, 5–20 mL, and 20–100 mL concentrators is approximately 15 µL, 30 µL, 50 µL, and 350 µL, respectively. To achieve >90% recovery of protein with the 0.5 mL concentrators, the minimum protein sample concentration should be 0.05 mg/mL. For all other concentrators, the minimum protein sample concentration should be 0.1 mg/mL. Optimal centrifuges and speeds The 0.5 mL concentrators can be used effectively at a maximum centrifugal force of 15,000 × g using a fixed angle centrifuge only. For the 2-6 mL concentrators, swinging-bucket or fixed-angle centrifuge models can be used. Swinging bucket centrifuges capable of generating 2,000–4,000 × g and a maximum centrifugal force of 4,000 × g are recommended. With fixed-angle centrifuges, models capable of generating 5,000–10,000 × g and a maximum centrifugal force of 8,000 × g are recommended. For the 5-20 mL volume concentrators, swinging-bucket or fixed-angle centrifuge models can be used. Swinging-bucket centrifuges capable of generating 2,000–5,000 × g and a maximum centrifugal force of 4,000 × g are recommended. With fixed-angle centrifuges, models capable of generating 5,000–8,000 × g and a maximum centrifugal force of 6,000 × g are recommended. For the 20-100 mL concentrators, only swinging-bucket centrifuges capable of generating 1,000–2,000 × g are recommended. Use a maximum centrifugal force of 2,000 × g. These concentrators are not recommended for use in fixed-angle rotors. Centrifugal force, temperature, sample volume, concentration, and viscosity will all affect filtration rate. Centrifugation time should therefore be optimized for each application.

Additional information
Filter Type

Membrane

Format

Spin Column, Spin Column (Microcentrifuge), 15 mL Conical, Spin Column, 50 mL Conical, Spin Column

Material (Membrane)

PES

MWCO

50 kDa

Sample Volume

20 to 100 mL, ≤0.5 mL, 2 to 6 mL, 5 to 20 mL

Max. RCF

Swinging-bucket rotor: 2,000 x g, Fixed-angle rotor: not recommended, 15,000 x g, Swinging-bucket rotor: 4,000 x g, Fixed-angle rotor: 10,000 x g, Swinging-bucket rotor: 5,000 x g, Fixed-angle rotor: 8,000 x g

Product Line

Pierce™

Quantity

4 Concentrators, 25 Concentrators, 10 Concentrators, 24 Concentrators

Shipping Condition

Room Temperature

Type

Protein Concentrator

Unit Size

4 concentrators, 25 concentrators, 10 concentrators, 24 concentrators

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Pierce™ Protein Concentrators PES, 50K MWCO, 0.5–100 mL” Cancel reply

Your email address will not be published. Required fields are marked *

Shipping & Delivery

Related products

Sold out
Placeholder
Placeholder
Compare
Сatalog number: 88535

Pierce™ Protein Concentrators PES, 10K MWCO, 0.5–100 mL

Ultrafiltration Filters and Devices
Quickly concentrate proteins and biological samples with Thermo Scientific Pierce Protein Concentrators PES (polyethersulfone), which are disposable ultrafiltration centrifugation devices that enable fast sample recovery and a short processing time. These concentrator columns can be used with standard microcentrifuge equipment, and samples can be collected without the need for invert spinning. Samples can be concentrated with or without desalting. These concentrators have a molecular weight cutoff (MWCO) of 10K and can be used for processing volumes from 0.5 to 100 mL.
Add to wishlist
Add To Quote
Quick view
Sold out
Placeholder
Placeholder
Compare
Сatalog number: 88536

Pierce™ Protein Concentrators PES, 30K MWCO

Ultrafiltration Filters and Devices
Easily and quickly concentrate 30K MWCO protein and biological samples with Thermo Scientific Pierce Protein Concentrators PES (polyethersulfone), which are disposable centrifugation devices that enable fast sample recovery and a short processing time. These concentrator columns can be used with standard microcentrifuge equipment, and samples can be collected without the need for invert spinning. Samples can be concentrated with or without desalting.
Add to wishlist
Add To Quote
Quick view
Sold out
Placeholder
Placeholder
Compare
Сatalog number: 88534

Pierce™ Protein Concentrators PES, 3K or 5K MWCO, 0.5–100 mL

Ultrafiltration Filters and Devices
Easily and quickly concentrate proteins and biological samples with Thermo Scientific Pierce Protein Concentrators PES (polyethersulfone), which are disposable centrifugation devices that enable fast sample recovery and a short processing time. These concentrator columns can be used with standard microcentrifuge equipment, and samples can be collected without the need for invert spinning. Samples can be concentrated with or without desalting. These products have a molecular weight cutoff (MWCO) of 3K or 5K and can be used for processing volumes of 0.5 to 100 mL.
Add to wishlist
Add To Quote
Quick view
Goldenbiotechnologies-EMEADIS-TICARET-LIMITED-SIRKETI

Golden Bio Technologies Corporation is a leading manufacturer and supplier of research and clinical laboratory equipment and reagents for worldwide diagnostics and research markets. It has been dedicated to helping develop an excellent diagnostics healthcare system nationwide by looking for affordable and most recent innovations in in-vitro diagnostics.

Contact

  • 8920 Vernon Ave., Suite 130, Montclair, CA 91763, USA
  • Phone: +1-909-931-1300
  • Fax: +1-909-360-4140
  • Email: info@goldenbiotechnologies.com

Quick Links

    • Home
    • Shop
    • About Us
    • Assay Development
    • R&D Services
    • Contact Us

Categories

    • Consumables
    • Equipments
    • Reagents/Assays
    • PCR
    • FERTILITY-Hormone
    • Ovulation Tests
Goldenbiotechnologies 2022
payments
  • Home
  • Shop
  • About us
  • Contact us
  • Wishlist
  • Compare
  • Login / Register
Shopping cart
close
Start typing to see products you are looking for.