Power | 100 ~ 240 VAC, 50-60 Hz, | ||||||||||||||||||||
Operating Temperature (ambient) | 0 – 50°C (32 – 122°F) | ||||||||||||||||||||
Operating Humidity (ambient) | 15 – 70% RH non-condensing | ||||||||||||||||||||
Warm up Time | < 5 min. | ||||||||||||||||||||
Dimensions | 135 X 419 X 217 mm (5.25″ X 16.5″ X 8.16″) | ||||||||||||||||||||
Weight | 1.35 kg (3 lb.) | ||||||||||||||||||||
Display Functions | 18 mm (0.7″) LCD readout, 4.5 digit Polarization Voltage (mV) Current input (nA, µA) | ||||||||||||||||||||
Controls | Power (on/off) Current Input Range Polarization Voltage |
||||||||||||||||||||
Analog Output Range | ±10 V (continuous) | ||||||||||||||||||||
Analog Output Impedance | 10 KΩ | ||||||||||||||||||||
Channel to Channel Isolation | >10 GΩ | ||||||||||||||||||||
Channel to Output Isolation | >10 GΩ | ||||||||||||||||||||
Power Supply to AC Line Isolation | >100 MΩ | ||||||||||||||||||||
Analog Output Drift | < 10 pA/hr. | ||||||||||||||||||||
Temperature Input: Number of Channels | 1 | ||||||||||||||||||||
Temperature Input: Sensing Element | Platinum RTD, 1000 Ω | ||||||||||||||||||||
Temperature Input: Range | 0-100°C | ||||||||||||||||||||
Temperature Input: Accuracy | ± 1°C | ||||||||||||||||||||
Temperature Input: Resolution | 0.1°C | ||||||||||||||||||||
Temperature Input: Analog Output | 31.25 mV/°C (continuous) | ||||||||||||||||||||
Amperometric Input: Number of Amperometric Channels | 4 | ||||||||||||||||||||
Amperometric Input: Signal Bandwidth | 0-3 Hz | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Nitric Oxide | 865 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Hydrogen Sulfide | 150 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Hydrogen Peroxide | 450 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Glucose | 600 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Oxygen | 700 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) ADJ (user adjustable) | ± 2500 mV | ||||||||||||||||||||
Polarization Voltage Accuracy | ± 5 mV | ||||||||||||||||||||
Polarization Voltage Display Resolution | ± 1mV | ||||||||||||||||||||
Current measurement Performance: |
|
||||||||||||||||||||
Notes: | *Instrument performance is measured as the (max-min) over 20 seconds period with open input. Typical values are given at 3 Hz and 0.3 Hz bandwidth. | ||||||||||||||||||||
Typical sensor performance with TBR4100: ISO-NOPF100 noise | 0.2 nM NO (< 2pA **) | ||||||||||||||||||||
Notes: | **Sensor noise is measured as the (max-min) over a 20 seconds period with the sensor immersed in 0.1 M CuCl2 solution. |
Product was successfully added to quote request.View Your Quote Cart

FOUR-CHANNEL FREE RADICAL ANALYZER
$9,831.00 – $11,317.00

ISO-COP-2 CARBON MONOXIDE SENSOR - 2MM
$1,354.00
ONE-CHANNEL FREE RADICAL ANALYZER
$4,914.00
Сatalog number:
TBR1025
Categories: Analyzers, Instruments/Platform, TBR1025 Analyzer
Description
Shipping & Delivery
Related products
Сatalog number:
5375
Low-noise cable for Microelectrode Holder, A: BNC (male), B: jack
$59.00
Сatalog number:
EZ-7000
Classic Small Animal Anesthesia System
$6,611.00
Complete small animal anesthesia system and all the accessories
EZ Anesthesia is the system of choice for anesthetizing small animals, and it comes with a variety of choices. Animals to be anesthetized are placed in the acrylic induction chamber, and the system delivers a precisely blended mixture of oxygen and isoflurane. An activated charcoal air filter canister at the top of the chamber releases safe, filtered air back into the room. A water-heated cage warmer or warming plate (ATC2000) is used to retain the animal body temperature while in the induction chamber. After the initial anesthetizing, the animal may be moved to the heated surgical water bed and positioned properly in the snugly fitted nose cone. A highly sensitive valve regulated by the animal’s breathing works with the nose cone to ensure non-rebreathing efficiency. It allows safe anesthesia for up to several hours. The breathing device also includes an air filter that releases safe, filtered air back into the room.Digital Anesthesia System
$7,765.00
E-Z Anesthesia® has taken the vaporizer to the next level. In an era of advancing technology, people have asked for the vaporizer to follow along with the digital trend. E-Z Anesthesia has taken the best of the both worlds and combined them into a very reliable, user-friendly, state-of-the-art system. The Digital Anesthesia System, AD-5000, enhances the always reliable TEC 3 vaporizer.
Сatalog number:
EZ-124DV
Anesthesia Oxygen Output Splitter
$0.00
ISO-NOPF Flexible Nitric Oxide Sensor
Analyzers, Amplifiers, Instruments/Platform, Free Radical Analyzers, Biosensors, Nitric Oxide Sensors
$1,251.00 – $1,792.00
ISO-NOPF electrodes are available in 100 µm, 200 µm and 500 µm diameters. Utilizing the latest advances in nano-technology and material science, scientists at WPI’s Sensor Laboratory have created these completely flexible and virtually unbreakable NO sensors. The new sensors are based on a composite graphite NO-sensing element combined with a reference electrode. The surface of the sens
Сatalog number:
5373
Low-Noise Cable for Microelectrode Holder, A: pin/jack, B: pin/jack
$35.00
Сatalog number:
DRL
Dummy Load Resistor Kit
$156.00
A365 can be used as a precise voltage source by placing a precision “dummy” resistor load across the output terminals. Precision resistors (such as the 100 Ω, 1000 Ω and 10,000 Ω resistors in WPI’s optional Dummy Load Resistor Kit #DRL) when placed across the output terminals convert the precision current levels to accurate voltage levels.
For example, 1 milliampere flowing through 1000 Ohms will produce 1 volt across the output terminal pair. Thus, models A365D and A365R can be used as low noise sources of accurate voltage pulses or DC. To maintain less than 1% error, avoid shunting the output dummy resistor with a load resistance less than 100 times the dummy resistance value.