Power | 100 ~ 240 VAC, 50-60 Hz, | ||||||||||||||||||||
Operating Temperature (ambient) | 0 – 50°C (32 – 122°F) | ||||||||||||||||||||
Operating Humidity (ambient) | 15 – 70% RH non-condensing | ||||||||||||||||||||
Warm up Time | < 5 min. | ||||||||||||||||||||
Dimensions | 135 X 419 X 217 mm (5.25″ X 16.5″ X 8.16″) | ||||||||||||||||||||
Weight | 1.35 kg (3 lb.) | ||||||||||||||||||||
Display Functions | 18 mm (0.7″) LCD readout, 4.5 digit Polarization Voltage (mV) Current input (nA, µA) | ||||||||||||||||||||
Controls | Power (on/off) Current Input Range Polarization Voltage |
||||||||||||||||||||
Analog Output Range | ±10 V (continuous) | ||||||||||||||||||||
Analog Output Impedance | 10 KΩ | ||||||||||||||||||||
Channel to Channel Isolation | >10 GΩ | ||||||||||||||||||||
Channel to Output Isolation | >10 GΩ | ||||||||||||||||||||
Power Supply to AC Line Isolation | >100 MΩ | ||||||||||||||||||||
Analog Output Drift | < 10 pA/hr. | ||||||||||||||||||||
Temperature Input: Number of Channels | 1 | ||||||||||||||||||||
Temperature Input: Sensing Element | Platinum RTD, 1000 Ω | ||||||||||||||||||||
Temperature Input: Range | 0-100°C | ||||||||||||||||||||
Temperature Input: Accuracy | ± 1°C | ||||||||||||||||||||
Temperature Input: Resolution | 0.1°C | ||||||||||||||||||||
Temperature Input: Analog Output | 31.25 mV/°C (continuous) | ||||||||||||||||||||
Amperometric Input: Number of Amperometric Channels | 4 | ||||||||||||||||||||
Amperometric Input: Signal Bandwidth | 0-3 Hz | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Nitric Oxide | 865 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Hydrogen Sulfide | 150 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Hydrogen Peroxide | 450 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Glucose | 600 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) Oxygen | 700 mV | ||||||||||||||||||||
Amperometric Input: Polarization Voltage (selectable via rotary switch) ADJ (user adjustable) | ± 2500 mV | ||||||||||||||||||||
Polarization Voltage Accuracy | ± 5 mV | ||||||||||||||||||||
Polarization Voltage Display Resolution | ± 1mV | ||||||||||||||||||||
Current measurement Performance: |
|
||||||||||||||||||||
Notes: | *Instrument performance is measured as the (max-min) over 20 seconds period with open input. Typical values are given at 3 Hz and 0.3 Hz bandwidth. | ||||||||||||||||||||
Typical sensor performance with TBR4100: ISO-NOPF100 noise | 0.2 nM NO (< 2pA **) | ||||||||||||||||||||
Notes: | **Sensor noise is measured as the (max-min) over a 20 seconds period with the sensor immersed in 0.1 M CuCl2 solution. |
Product was successfully added to quote request.View Your Quote Cart

FOUR-CHANNEL FREE RADICAL ANALYZER
$9,831.00 – $11,317.00

ISO-COP-2 CARBON MONOXIDE SENSOR - 2MM
$1,354.00
ONE-CHANNEL FREE RADICAL ANALYZER
$4,914.00
Сatalog number:
TBR1025
Categories: Analyzers, Instruments/Platform, TBR1025 Analyzer
Description
Shipping & Delivery
Related products
Micro Nitric Oxide Sensors
$1,027.00 – $1,074.00
The ISO-NOP007 has a tip diameter of just 7 microns and a length of 2mm. The response is linear over a wide dynamic concentration range of NO. The design is based on a single carbon fiber coated with WPI's NO-selective membrane. A detection limit of approximately 1 nM NO makes this electrode ideal for use in tissues and microvessels.
Euthanex Lid Gaskets
$48.00 – $85.00
Сatalog number:
CPVC4050G
Carbon, 18 AWG, green
$0.00
Сatalog number:
DRL
Dummy Load Resistor Kit
$156.00
A365 can be used as a precise voltage source by placing a precision “dummy” resistor load across the output terminals. Precision resistors (such as the 100 Ω, 1000 Ω and 10,000 Ω resistors in WPI’s optional Dummy Load Resistor Kit #DRL) when placed across the output terminals convert the precision current levels to accurate voltage levels.
For example, 1 milliampere flowing through 1000 Ohms will produce 1 volt across the output terminal pair. Thus, models A365D and A365R can be used as low noise sources of accurate voltage pulses or DC. To maintain less than 1% error, avoid shunting the output dummy resistor with a load resistance less than 100 times the dummy resistance value.
ISO-NOPF Flexible Nitric Oxide Sensor
Analyzers, Amplifiers, Instruments/Platform, Free Radical Analyzers, Biosensors, Nitric Oxide Sensors
$1,251.00 – $1,792.00
ISO-NOPF electrodes are available in 100 µm, 200 µm and 500 µm diameters. Utilizing the latest advances in nano-technology and material science, scientists at WPI’s Sensor Laboratory have created these completely flexible and virtually unbreakable NO sensors. The new sensors are based on a composite graphite NO-sensing element combined with a reference electrode. The surface of the sens