Showing 61–72 of 98 results

Сatalog number: ISO-COP-2

ISO-COP-2 CARBON MONOXIDE SENSOR – 2MM

Carbon monoxide (CO) is a versatile mediator of physiological processes. Carbon monoxide (CO) formed by internal mechanisms (endogenous) is measured in a variety of ways, but standard measurement methods are of limited utility in most biological systems.  WPI's ingenious ISO-COP-2 CO sensor measures CO in vivo or in vitro in real time!

ISO-NOPF Flexible Nitric Oxide Sensor

ISO-NOPF electrodes are available in 100 µm, 200 µm and 500 µm diameters. Utilizing the latest advances in nano-technology and material science, scientists at WPI’s Sensor Laboratory have created these completely flexible and virtually unbreakable NO sensors. The new sensors are based on a composite graphite NO-sensing element combined with a reference electrode. The surface of the sens
Сatalog number: ISO-NOPNM

ISO-NOPNM NITRIC OXIDE SENSOR – 100NM

The ISO-NOPNM is based on a novel design in which an electrochemically "activated" composite graphite nanofiber is used as the NO-sensing element. The surface of the Nanosensor is then modified using a unique multi-layered NO-selective membrane. Figure at right illustrates the response of the ISO-NOPNM following successive additions of nanomolar concentrations of NO. The ultra-low noise of the ISO-NOPNM (0.5 pA) enables a detection limit of just 0.5 nM NO. The response time of ISO-NOPNM is less than 3 seconds.
Сatalog number: 300344

LAB-TRAX 4/24 T CABLE

This cable probides a single-ended input to the LAB-TRAX-4-24T input for general recording (non-transducer).
Сatalog number: AB-TRAX-4

LABTRAX 4-CHANNEL DATA ACQUISITION

The Lab-Trax-4 (standard) device offers 16-bit resolution over the ±10V input range and exhibit less than a millivolt of noise. Data communication as well as power is managed over the USB port, making it easy to use a laptop or a low-profile desktop computer that may not be equipped with expansion slots or serial ports. Data is delivered to the recorder by way of very standard front-panel-mounted BNC connectors. The available Lab-Trax hardware together with WPI’s range of signal conditioners and the LabScribe software make it the perfect choice for research systems addressing cardiovascular studies, blood pressure, cardiac electrophysiology, hemodynamic studies of the pulmonary and coronary systems, and studies of isolated tissues in organ or tissue baths. Equipment from WPI can also be used to tailor systems for epithelial studies, and many applications in neurophysiology.

Linear Stimulus Isolator

Model A395 generates a user-defined output current of wave shape; DC, AC, pulse and combinations. Battery operated, pho­to­elec­tri­cal­ly-isolated from the input voltage drive, the instrument regen­er­ates out­put currents which are linearly proportional to the analog voltage wave­forms pro­vid­ed by your D/A con­vert­er or sig­nal generator.
Сatalog number: 5375

Low-noise cable for Microelectrode Holder, A: BNC (male), B: jack

For wiring any laboratory setup This standard cable has a male BNC connector on one end and a 2mm gold
Сatalog number: 5374

Low-noise cable for Microelectrode Holder, A: BNC (male), B: pin

For wiring any laboratory setup This standard cable has a male BNC connector on one end and a 2mm gold
Сatalog number: 5373

Low-Noise Cable for Microelectrode Holder, A: pin/jack, B: pin/jack

Standard electrophysiology application cable
This cable has a pin/jack connector on both ends and is 2' (0.6m) long.